NSF INTERNATIONAL®
NSF International, The Public Health and Safety Company - a not for profit, non-governmental organization, is the world leader in standards development, product certification, education, and risk-management for public health and safety. For more than 59 years, NSF has been committed to public health, safety, and protection of the environment. While focusing on food, water, indoor air, and the environment, NSF develops national standards, provides learning opportunities through its Center for Public Health Education, and provides third-party conformity assessment services while representing the interests of all stakeholders.If you would like more information on NSF's drinking water treatment program, you can visit their web site at http://www.nsf.org See NSF's Official Listing Of Contaminants Reduced By Multi-Pure Water Filters See The NSF Video
View & Compare Multi-Pure's Superior Performance - Confirmed by NSF's Testing and Certification.
Multi-Pure Drinking Water Filters National Sanitation Foundation Certification Information
The effectiveness of any drinking water purification or water treatment device is measured by the performance of its water filter.
NSF testing in accordance with NSF/ANSI standards provides the consumer with the highest level of assurance that certified products will perform as claimed...
A close review of NSF Listings shows that MultiPure’s solid carbon block water filters are the most effective for reducing a broad spectrum of contaminants of aesthetic as well as health concern....
Performance Data Sheet For MultiPure Water Filters
Percentages Of Contaminant Reduction Based Upon MultiPure's NSF Certifications
Multi-Pure Models MP750SB, MP1200EL, MP750SC, MP750SI, MPAD, MPCT Have Been Tested And Certified By NSF
Standard 42 (Aesthetic Effects)
Substance Percent Reduction
Chloramine 97%
Chlorine 99%
Particulates Class 1 0.5 Micron < 1.0 Micron 99%
Taste and Odor Reduction
NSF Certified Standard 53
Substance Percent Reduction
Alachlor 98%
Asbestos 99.9% 107 to 108 fibers/L; fibers greater than 10 micrometers in length
99% reduction requirement...
Atrazine 97%
Benzene 99%
Bromodichloromethane (TTHM) 99.8%
Bromoform (TTHM) 99.8%
Carbofuran (Furadan) 99%
Carbon Tetrachloride 98%
Chlordane 99.5%
Chlorobenzene (Monochlorobenzene) 99%
Chloropicrin 99%
Chloroform (TTHM)* (surrogate chemical) 99.8%
Cryptosporidium (CYST) 99.95% minimum
CYST (Giardia; Cryptosporidium; Entamoeba; Toxoplasma) 99.95% minimum
2, 4-D 98%
DBCP (see Dibromochloropropane) 99%
1,2-DCA (see 1,2-Dichloroethane) 95%
1,1-DCE (see 1,1-Dichloroethylene) 99%
Dibromochloromethane (TTHM;Chlorodibromomethane) 99.8%
Dibromochloropropane (DBCP) 99%
o-Dichlorobenzene (1,2 Dichlorobenzene) 99%
p-Dichlorobenzene (para-Dichlorobenzene) 98%
1,2-Dichloroethane (1,2-DCA) 95%
1,1-Dichloroethylene (1,1-DCE) 99%
CIS-1,2-Dichloroethylene 99%
Trans-1,2- Dichloroethylene 99%
1,2-Dichloropropane (Propylene Dichloride) 99%
CIS-1,3- Dichloropropylene 99%
Dinoseb 99%
EDB (see Ethylene Dibromide) 99%
Endrin 99%
Entamoeba (see CYSTS) 99.95% minimum
Ethylbenzene 99%
Ethylene Dibromide (EDB) 99%
Furadan (see Carbofuran) 99%
Giardia Lamblia 99.95%
Haloacetonitriles:
Bromochloroacetonitrile 98%
Dibromoacetonitrile 98%
Dichloroacetonitrile 98%
Trichloroacetonitrile 98%
Haloketones:
1,1-Dichloro-2-Propanone 99%
1,1,1-Trichloro-2-Propanone 96%
Heptachlor 99%
Heptachlor Epoxide 98%
Hexachlorobutadiene (Perchlorobutadiene) 98%
Hexachlorocyclopentadiene 99%
Lead (pH 6.5) 99.3%
Lead (pH 8.5) 99.3%
Lindane 99%
Mercury (pH 6.5) 99%
Mercury (pH 8.5) 99%
Methoxychlor 99%
Methylbenzene (see Toluene) 99%
Monochlorobenzene (see Chlorobenzene) 99%
MTBE (methyl tert-butyl ether) 96.6%
Polychlorinated Biphenyls (PCBs , Aroclor 1260) 99.9%
PCE (see Tetrachloroethylene) 99%
Pentachlorophenol 99%
Perchlorobutadiene (see Hexachlorobutadiene) 98%
Propylene Dichloride (see 1,2 -Dichloropropane) 99%
Simazine 97%
Silvex (see 2,4,5-TP) 99%
Styrene (Vinylbenzene) 99%
1,1,1-TCA (see 1,1,1 - Trichloroethane) 95%
TCE (see Trichloroethylene) 99%
1,1,2,2- Tetrachloroethane 99%
Tetrachloroethylene 99%
Toluene (Methylbenzene) 99%
Toxaphene 92.9%
Toxoplasma (see Cysts) 99.95%
2,4,5-TP (Silvex) 99%
Tribromoacetic Acid
1,2,4 Trichlorobenzene (Unsymtrichlorobenzene) 99%
1,1,1-Trichloroethane (1,1,1-TCA) 95%
1,1,2-Trichloroethane 99%
Trichloroethylene (TCE) 99%
Trihalomethanes (TTHM) (Chloroform; Bromoform;
Bromodichloromethane; Dibromochloromethane) 99.8%
Turbidity 99%
Trichlorobenzene 99%
Vinylbenzene (see Styrene) 99%
Xylenes 99%
Approximate Service Capacity - Model MP750 - 750 gallons Model 1200EL- 1200 gallons MPAD - 750 gallons
Replacement Filter Type Model No./ Approx. Cost CB6/$60 CB6/$60 CBAD/$60
Approximate Flow Rate @ 60 psi 0.75 gpm 0.75 gpm 0.75 gpm
Maximum Water Pressure 100 psi/7.0 kg/cm2 100 psi/7.0 kg/cm2 100 psi/7.0 kg/cm2
Minimum Water Pressure 30 psi/2.1 kg/cm2 30 psi/2.1 kg/cm2 30 psi/2.1 kg/cm2
Maximum Operating Temperature 100°F/38°C
Minimum Operating Temperature 32°F/0°C
For Cold Water Use Only 32°F/0°C
Warranty on Housing: Lifetime
Warranty on Exterior Hoses and Attachments 1 year 1 year 1 year
Models MP880SB MP880EL MP880SC Arsenic Water Filters
Tested And Certified By NSF To Standard 42
Standard 42 (Aesthetic Effects)
Substance Percent Reduction
Chloramine 97%
Chlorine 99%
Particulates Class 1 0.5 Micron < 1.0 Micron 99%
Taste and Odor Reduction
MultiPure MP880 Water Filters Are Tested And Certified By NSF To Standard 53 For:
Substance Percent Reduction
Alachlor 98%
Arsenic pentavalent As (V); As (+5); arsenate @ 6.5 pH 99.9%
Arsenic pentavalent As (V); As (+5); arsenate @ 8.5 pH 95.8%
Asbestos 99.9% 107 to 108 fibers/L; fibers greater than 10 micrometers in length
99% reduction requirement...
Atrazine 97%
Benzene 99%
Bromodichloromethane (TTHM) 99.8%
Bromoform (TTHM) 99.8%
Carbofuran (Furadan) 99%
Carbon Tetrachloride 98%
Chlordane 99.5%
Chlorobenzene (Monochlorobenzene) 99%
Chloropicrin 99%
Chloroform (TTHM)* (surrogate chemical) 99.8%
Cryptosporidium (CYST) 99.95% minimum
CYST (Giardia; Cryptosporidium; Entamoeba; Toxoplasma) 99.95% minimum
2, 4-D 98%
DBCP (see Dibromochloropropane) 99%
1,2-DCA (see 1,2-Dichloroethane) 95%
1,1-DCE (see 1,1-Dichloroethylene) 99%
Dibromochloromethane (TTHM;Chlorodibromomethane) 99.8%
Dibromochloropropane (DBCP) 99%
o-Dichlorobenzene (1,2 Dichlorobenzene) 99%
p-Dichlorobenzene (para-Dichlorobenzene) 98%
1,2-Dichloroethane (1,2-DCA) 95%
1,1-Dichloroethylene (1,1-DCE) 99%
CIS-1,2-Dichloroethylene 99%
Trans-1,2- Dichloroethylene 99%
1,2-Dichloropropane (Propylene Dichloride) 99%
CIS-1,3- Dichloropropylene 99%
Dinoseb 99%
EDB (see Ethylene Dibromide) 99%
Endrin 99%
Entamoeba (see CYSTS) 99.95% minimum
Ethylbenzene 99%
Ethylene Dibromide (EDB) 99%
Furadan (see Carbofuran) 99%
Giardia Lamblia 99.95%
Haloacetonitriles:
Bromochloroacetonitrile 98%
Dibromoacetonitrile 98%
Dichloroacetonitrile 98%
Trichloroacetonitrile 98%
Haloketones:
1,1-Dichloro-2-Propanone 99%
1,1,1-Trichloro-2-Propanone 96%
Heptachlor 99%
Heptachlor Epoxide 98%
Hexachlorobutadiene (Perchlorobutadiene) 98%
Hexachlorocyclopentadiene 99%
Lead (pH 6.5) 99.3%
Lead (pH 8.5) 99.3%
Lindane 99%
Mercury (pH 6.5) 99%
Mercury (pH 8.5) 99%
Methoxychlor 99%
Methylbenzene (see Toluene) 99%
Monochlorobenzene (see Chlorobenzene) 99%
MTBE (methyl tert-butyl ether) 96.6%
Polychlorinated Biphenyls (PCBs , Aroclor 1260) 99.9%
PCE (see Tetrachloroethylene) 99%
Pentachlorophenol 99%
Perchlorobutadiene (see Hexachlorobutadiene) 98%
Propylene Dichloride (see 1,2 -Dichloropropane) 99%
Simazine 97%
Silvex (see 2,4,5-TP) 99%
Styrene (Vinylbenzene) 99%
1,1,1-TCA (see 1,1,1 - Trichloroethane) 95%
TCE (see Trichloroethylene) 99%
1,1,2,2- Tetrachloroethane 99%
Tetrachloroethylene 99%
Toluene (Methylbenzene) 99%
Toxaphene 92.9%
Toxoplasma (see Cysts) 99.95%
2,4,5-TP (Silvex) 99%
Tribromoacetic Acid
1,2,4 Trichlorobenzene (Unsymtrichlorobenzene) 99%
1,1,1-Trichloroethane (1,1,1-TCA) 95%
1,1,2-Trichloroethane 99%
Trichloroethylene (TCE) 99%
Trihalomethanes (TTHM) (Chloroform; Bromoform;
Bromodichloromethane; Dibromochloromethane) 99.8%
Turbidity 99%
Trichlorobenzene 99%
Vinylbenzene (see Styrene) 99%
Xylenes 99%
NOTES:
1. Multi-Pure Drinking Water Systems have been certified, as indicated, by NSF International for compliance to
NSF/ANSI Standard Nos. 42 & 53.
2. The Multi-Pure Drinking Water Systems have been certified by the State of California Department of Health Services
for the reduction of specific contaminants listed herein.
3. Chloroform was used as a surrogate for claims of reduction of VOCs. MultiPure Systems tested at >99.8% actual
reduction of Chloroform. Percent reduction shown herein reflects the allowable claims for VOCs as per tables in
the Standard for water filtration systems.
4. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or
after the water filtration system. Multi-Pure Water Filtration Systems certified for cyst reduction may be used on disinfected
water that may contain filterable cysts.
5. Filter life will vary in proportion to the amount of water used and the level of impurities in the water being processed. For optimum
performance, it is essential that the filter be replaced on a regularly scheduled basis as follows: (a) annually; (b) when the unit’s
rated capacity has been reached; (c) the flow rate diminishes; (d) the filter becomes saturated with bad tastes and odors.
6. MultiPure Model No. MP1200EL includes a capacity monitor that automatically flashes a yellow light when it is time to replace
your internal water filter.
7. Multi-Pure Drinking Water Filtration Housings are warranted for Lifetime (*provided that the internal water filter be replaced at least
once a year)... All exterior hoses and attachments to the System are warranted for one year. Please see the MultiPure Water
Filters Owner’s Manual for complete product guarantee and warranty information.
8. Please see the MultiPure Owner’s Manual for installation instructions and operating procedures of the water filter.
9. In compliance with New York law, it is recommended that before purchasing a water purification system, NY residents have their
water supply tested to determine their actual water treatment needs. Please compare the capabilities of the Multi-Pure water
filter with your actual water treatment needs.
10. Check for compliance with state and local laws and regulations that apply to water filters.
11. While testing was performed under standard laboratory conditions, actual performance may vary to some degree depending
upon water quality and water pressure. Water that contains an excessively high level of solid materials, particles, and/or an
excessively high level of contaminants may cause the water filter to reach capacity sooner than one year...
Excessively high water pressure can cause the water to be forced through the filter too quickly reducing the time the water is
exposed to the carbon reducing the water filters ability to properly absorb contaminants from the water...
12. The list of substances which the MultiPure Water Filters reduce does not necessarily mean that these substances are present
in your tap water.
Operational Specifications For Multi-Pure Water Filters - MP880SB MP880SC MP880SI MP880EL
Approximate Service Capacity (6) 600 Gallons 600 Gallons 600 Gallons 960 Gallons
Replacement Filter Model No./ Approx. Cost CB11AS/$110 CB11AS/$110 CB11AS/$110 CB11AS/$110
Approximate Flow Rate @ 60 psi 1.0 gpm 1.0 gpm 1.0 gpm 1.0 gpm
Maximum Water Pressure 100 psi/7.03 kg/cm2 100 psi/7.03 kg/cm2 100 psi/7.03 kg/cm2 100 psi/7.03 kg/cm2
Minimum Water Pressure 30 psi/2.1 kg/cm2 30 psi/2.1 kg/cm2 30 psi/2.1 kg/cm2 30 psi/2.1 kg/cm2
Maximum Operating Temperature 100°F/38°C for cold water use only...
Minimum Operating Temperature 32°F/0°C
Certification Data For MultiPure Reverse Osmosis Water Filter Model MP750Plus RO
Multi-Pure Model No. MP750PlusRO Drinking Water Systems have been tested and certified under NSF Standard Nos. 42, 53 and 58 as shown below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 53, Health Effects.
NSF/ANSI 42 - Aesthetic Effects
MultiPure Water Filter Model MP750PlusRO has been tested according to NSF/ANSI Standard 42 for the reduction of the following substances. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system.
Tested By NSF To NSF Standard 42:
Substance Percent Reduction
CHLORAMINE as Aesthetic Effect (As Monochloramine) 97%
CHLORINE as Aesthetic Effect 99%
PARTICULATE, (Nominal Particulate Reduction, Class I, Particles 0.5 TO <1 UM Class I > 99%
Taste and Odor
NSF/ANSI Standard 53:
Substance Percent Reduction
Alachlor 98%
Asbestos 99.9% 107 to 108 fibers/L; fibers greater than 10 micrometers in length 99% reduction
Atrazine 97%
Benzene 99%
Bromodichloromethane (TTHM) 99.8%
Bromoform (TTHM) 99.8%
Carbofuran (Furadan) 99%
Carbon Tetrachloride 98%
Chlordane 99.5%
Chlorobenzene (Monochlorobenzene) 99%
Chloropicrin 99%
Chloroform (TTHM)* (surrogate chemical) 99.8%
Cryptosporidium (CYST) 99.95% minimum
CYST (Giardia; Cryptosporidium; Entamoeba; Toxoplasma) 99.95% minimum
2, 4-D 98%
DBCP (see Dibromochloropropane) 99%
1,2-DCA (see 1,2-Dichloroethane) 95%
1,1-DCE (see 1,1-Dichloroethylene) 99%
Dibromochloromethane (TTHM;Chlorodibromomethane) 99.8%
Dibromochloropropane (DBCP) 99%
o-Dichlorobenzene (1,2 Dichlorobenzene) 99%
p-Dichlorobenzene (para-Dichlorobenzene) 98%
1,2-Dichloroethane (1,2-DCA) 95%
1,1-Dichloroethylene (1,1-DCE) 99%
CIS-1,2-Dichloroethylene 99%
Trans-1,2- Dichloroethylene 99%
1,2-Dichloropropane (Propylene Dichloride) 99%
CIS-1,3- Dichloropropylene 99%
Dinoseb 99%
EDB (see Ethylene Dibromide) 99%
Endrin 99%
Entamoeba (see CYSTS) 99.95% minimum
Ethylbenzene 99%
Ethylene Dibromide (EDB) 99%
Furadan (see Carbofuran) 99%
Giardia Lamblia 99.95%
Haloacetonitriles:
Bromochloroacetonitrile 98%
Dibromoacetonitrile 98%
Dichloroacetonitrile 98%
Trichloroacetonitrile 98%
Haloketones:
1,1-Dichloro-2-Propanone 99%
1,1,1-Trichloro-2-Propanone 96%
Heptachlor 99%
Heptachlor Epoxide 98%
Hexachlorobutadiene (Perchlorobutadiene) 98%
Hexachlorocyclopentadiene 99%
Lead (pH 6.5) 99.3%
Lead (pH 8.5) 99.3%
Lindane 99%
Mercury (pH 6.5) 99%
Mercury (pH 8.5) 99%
Methoxychlor 99%
Methylbenzene (see Toluene) 99%
Monochlorobenzene (see Chlorobenzene) 99%
MTBE (methyl tert-butyl ether) 96.6%
Polychlorinated Biphenyls (PCBs , Aroclor 1260) 99.9%
PCE (see Tetrachloroethylene) 99%
Pentachlorophenol 99%
Perchlorobutadiene (see Hexachlorobutadiene) 98%
Propylene Dichloride (see 1,2 -Dichloropropane) 99%
Simazine 97%
Silvex (see 2,4,5-TP) 99%
Styrene (Vinylbenzene) 99%
1,1,1-TCA (see 1,1,1 - Trichloroethane) 95%
TCE (see Trichloroethylene) 99%
1,1,2,2- Tetrachloroethane 99%
Tetrachloroethylene 99%
Toluene (Methylbenzene) 99%
Toxaphene 92.9%
Toxoplasma (see Cysts) 99.95%
2,4,5-TP (Silvex) 99%
Tribromoacetic Acid
1,2,4 Trichlorobenzene (Unsymtrichlorobenzene) 99%
1,1,1-Trichloroethane (1,1,1-TCA) 95%
1,1,2-Trichloroethane 99%
Trichloroethylene (TCE) 99%
Trihalomethanes (TTHM) (Chloroform; Bromoform;
Bromodichloromethane; Dibromochloromethane) 99.8%
Turbidity 99%
Trichlorobenzene 99%
Vinylbenzene (see Styrene) 99%
Xylenes 99%
NSF/ANSI 58 - Reverse Osmosis
Multi-Pure Reverse Osmosis Water Filters Model MP750PlusRO have been tested according to NSF/ANSI Standard 58 for the reduction of the following substances. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 58
Arsenic V (pentavalent As (V); As(+5); arsenate) 98.4% 0.30 +/- 10% 0.010
Barium 97.9% 10.0 +/- 10% 2.0
Cadmium 98.6% 0.03 +/- 10% 0.005
Chromium, Hexavalent 91.3% 0.3 +/- 10% 0.1
Chromium, Trivalent 94.1% 0.3 +/- 10% 0.1
Copper 99.0% 3.0 +/- 10% 1.3
Cyst (Giardia; Cryptosporidium; Entamoeba;Toxoplasma) 99.99% 50,000 mL 0.9995
Fluoride 93.9% 8.0 +/- 10% 1.5
Lead 98.6% 0.15 +/- 10% 0.010
Nitrate 92.0% 30.0 +/- 10% 10.0
Nitrite 89.0% 3.0 +/- 10% 1.0
Nitrate/Nitrite 91.2% 30.0 +/- 10% 10.0
Perchlorate 96.5% 0.10 +/- 10% 0.006
Radium 226/228 80.0% 25 pCi/L +/- 10% 5 pCi/L
Selenium 92.0% 0.10 +/- 10% 0.05
Total Dissolved Solids (TDS) 96.8% 750 +/- 40 mg/L 187
NSF/ANSI 58 - Reverse Osmosis
MultiPure Reverse Osmosis Water Filters Model MP750PlusRO have been tested according to NSF/ANSI Standard 58 for the reduction of the following substances. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 58.
NOTES:
1. Multi-Pure Drinking Water Systems have been certified, as indicated, by NSF International for compliance to NSF/ANSI Standard
Nos. 42 and 53, and 58.
2. This Multi-Pure Drinking Water System(s) have been certified by the State of California Department of Health Services for the
reduction of specific contaminants listed herein.
3. Chloroform was used as a surrogate for claims of reduction of Volatile Organic Chemicals (VOC). Multi-Pure Systems tested at
>99.8% actual reduction of Chloroform. Percent reduction shown herein reflects the allowable claims for VOCs as per tables in the
Standard.
4. Do not use with water that is microbiologically unsafe or with water of unknown quality without adequate disinfection
before or after the unit. Systems certified for cyst reduction may be used on disinfected waters that may contain
filterable cysts.
5. The System may be used with municipal or well water sources that are treated and tested on a regular basis to ensure
bacteriological safe quality of the water.
6. Do not allow water to freeze in the unit. If unit is exposed to freezing temperatures, drain water from unit and remove filters.
7. Do not allow water to sit in unit for extended periods of time (10 or more days) without being used. If unit is to be left unused for
more than 10 days, drain all water from the system and remove the filters. Upon your return, reconnect the filters in the housing
and continue use. In the event water does sit in the unit for 10 or more days, the system should be flushed by allowing water to
flow to waste for about 10 minutes; then continue use as normal.
8. Multi-Pure Drinking Water System Housings are warranted for Lifetime (provided that the filter be replaced at least once a year).
All exterior hoses and attachments to the System are warranted for defects in material and workmanship for one year. Please
see the Owner’s Manual for complete product guarantee and warranty information.
9. Please see the Owner’s Manual for installation instructions and operating procedures.
10. In compliance with New York law, it is recommended that before purchasing a water treatment system, NY residents have their
water supply tested to determine their actual water treatment needs. Please compare the capabilities of the Multi-Pure unit with
your actual water treatment needs.
11. Check for compliance with state and local laws and regulations.
12. While testing was performed under standard laboratory conditions, actual performance may vary.
13. The list of substances which the treatment device reduces does not necessarily mean that these substances are present in your
tap water.
14. This system is acceptable for treatment of influent concentrations of no more than 27 mg/L nitrate and 3 mg/L nitrite in
combination measured as N and is certified for nitrate/nitrite reduction only for water supplies with a pressure of 280 kPa (40
psig) or greater.
15. This system has been tested for the treatment of water containing pentavalent arsenic (also known as As(V), As(+5), or
arsenate) at concentrations of 0.30 mg/L or less. This system reduces pentavalent arsenic, but may not remove other forms of
arsenic.
This system is to be used on water supplies containing a detectable free chlorine residual at the system inlet or on water supplies that have been demonstrated to contain only pentavalent arsenic. Treatment with chloramine (combined chlorine) is not sufficient to ensure complete conversion of trivalent arsenic to pentavalent arsenic. Please see the Arsenic Facts section of the Performance Data Sheet for further information.
Multi-Pure Reverse Osmosis Water Filters Model MP750PlusRO Operation and Maintenance Specifications
Depending on water chemistry, water temperature, and water pressure, the MultiPure Reverse Osmosis Water Filters MP750PlusRO Reverse Osmosis Systems production and performance will vary. Refer to Owner’s Manual for further maintenance requirements and warranty information
General Use Conditions:
Maximum Operating Temperature 100°F / 40.5°C
Minimum Operating Temperature 40°F /0°C
Maximum Working Pressure 100 psi / 7.0 kg/cm2
The operating pressure in your home should be tested over a 24
hour period to attain the maximum pressure. If it is over 100 psi then
a pressure regulator will be required.
Minimum Working Pressure 40 psi / 2.8 kg/cm2
pH parameters 3 pH to 11 pH
Iron 0.2 ppm maximum
TDS (total dissolved solids) < 1800 ppm
Turbidity < 5 NTU
Hardness
< 10 grains per gallon /
171 mg/L of hardness as
CaCO3
MultiPure Reverse Osmosis Water Filters will operate with hardness over 10 grains, but the reverse osmosis membrane life may be shortened. Multi-Pure Model MP750PlusRO Reverse Osmosis Water Filters work inconjunction with 3 prefilters prior to the reverse osmosis membrane to reduce the chances of the reverse osmosis membrane being contaminated with particles and solids that can cause the lifespan of the reverse osmosis membrane to be shortened...
Specifications:
Average influent TDS 765 mg/L
Average effluent TDS 23 mg/L
Daily Production Rate (DPR) 17.32 gpd Gallons produced per day
Efficiency Rating 8.91%
Efficiency rating means the percentage of the influent water to the Multi-Pure Reverse Osmosis Systems that is available to the user as reverse osmosis treated water under operating conditions that approximate typical daily usage.
Recovery Rating 16.34%
Recovery rating means the percentage of the influent water to the reverse osmosis membrane portion of the MultiPure MP750PlusRO Reverse Osmosis System that is available to the user as reverse osmosis treated water when the system is operated without a storage tank or when the storage tank is bypassed.
Capacity of Tank 1.8 - 2.5 gallons Depending on the incoming water pressure.
Approximate Flow Rate @ 60 psi 0.50 gpm
MP750 Plus RO Operation and Maintenance Specifications
Depending on water chemistry, water temperature, and water pressure, the MP750 Plus RO System production and performance will vary. Refer to Owner’s Manual for further maintenance requirements and warranty information.
Note: This Performance Data Sheet addresses the U.S. Environmental Protection Agency (USEPA) Primary and Secondary Drinking Water Regulations in effect at its time of publication, as they related to Multi-Pure's performance in conformance to the industry performance criteria. These regulations are continually being updated at the Federal level. Accordingly, this list of MCLs will be reviewed and amended when appropriate. Please see sales brochure for list of product certifications.
Replacement Filters and Parts
Filter life will vary in proportion to the amount of water used and the level of impurities in the water being processed. Replacement filters, membrane, and parts can be purchased directly from Multi-Pure Corporation. Replacement filter model numbers are shown below. The approximate retail price of replacement filters is also shown below. Prices exclude sales tax and shipping and handling fees (*prices subject to change without notice).
To dispose of the used filter or membrane, remove it from the housing and place the old filter or membrane in your normal refuse. Carbon filters disposed of in a normal landfill will not release any chemical contamination but will probably continue to adsorb additional contaminants that are disposed of in landfills.
Description Model No.
Recommended Change
Schedule
Approximate
Price*
Sediment Pre-Filter (Stage 1) CBC110 6 months $5.00
5 micron Carbon Pre-Filter (Stages 2 & 3) CBC112 6 months $13.00
Sub micron Carbon Post-Filter CB6 750 gallons (at least once a year) $60.00
RO membrane CB-ROM 2 to 3 years $100.00
California Department of Public Health
Certification / Registration
Facts About Arsenic (in compliance with NSF Standard 58)
Arsenic (abbreviated As) is a naturally occurring contaminant found in many ground waters. Arsenic in water has no color, taste or odor. It must be measured by a lab test. Public water utilities must have their water tested for arsenic. You can get the results from your water utility. If you have your own well, you can have the water tested.
The local health department or the state environmental health agency can provide a list of certified labs. The cost is typically $15 to $30.
Information about arsenic in water can be found on the Internet at the US Environmental Protection Agency website:
www.epa.gov/safewater/arsenic.html.
There are two forms of arsenic: pentavalent arsenic (also called As(V), As(+5), and arsenate) and trivalent arsenic (also called As(III), As(+3), and arsenite).
In well water, arsenic may be pentavalent, trivalent, or a combination of both.
Special sampling procedures are needed for a lab to determine what type and how much of each type of arsenic is in the water. Check with the labs in your area to see if they can provide this type of service.
Reverse Osmosis (RO) systems are very effective at removing pentavalent arsenic. However, RO systems do not remove trivalent arsenic from water very well. A free chlorine residual will rapidly convert trivalent arsenic to pentavalent arsenic. Other water treatment chemicals such as ozone and potassium permanganate will also change trivalent arsenic to pentavalent arsenic. A combined chlorine residual (also called chloramine) may not convert all the trivalent arsenic. If you get your water from a public water utility, contact the utility to find out if free chlorine or combined chlorine is used in the water system.
Multi-Pure MP750PlusRO Reverse Osmosis Water Filters are designed to remove only pentavalent arsenic. It will not convert trivalent arsenic to pentavalent arsenic.
The MultiPure MP750PlusRO Reverse Osmosis System was tested in a laboratory to remove pentavalent arsenic. Under lab conditions, as defined in NSF/ANSI Standard 58, the system reduced 0.30 mg/L (ppm) pentavalent arsenic to 0.010 mg/L (ppm) (the USEPA standard for drinking water) or less. The performance of the MultiPure Reverse Osmosis System may be different at your installation. Have the treated water tested for arsenic to check if the system is working properly.
The RO component (reverse osmosis membrane) of the Multi-Pure MP750PlusRO Reverse Osmosis Water Filter must be replaced as indicated in the Owner's Manual to ensure the water filtration system will continue to remove arsenic and other contaminants. The component identification and locations where you can purchase the component are listed in the installation/operation manual.
Multi-Pure Corporation
7251 Cathedral Rock Drive
Las Vegas, NV 89128
800-622-9206 · 702-360-8880
email: headquarters@multipure.com